High-voltage Diesel Generator Set

  • High-voltage Diesel Generator Set
  • High-voltage Diesel Generator Set
  • video
  • Huamin
  • China
  • 5-10 days
  • 1000 pieces a year
High-voltage generator feature stable voltage, high efficiency and low loss, suitable for long-distance high-power transmission
High-voltage generator sets are highly efficient power supply equipment specially designed for high-power and long-distance power supply. With typical voltage ratings of 6kV and 10kV, they integrate high-quality high-voltage engines, high-voltage alternators and intelligent control systems as core components. Adopting mature manufacturing technology, the units feature compact structure, small footprint and adaptability to various complex installation environments.

They deliver outstanding advantages including stable voltage, high efficiency and low loss, with power generation efficiency exceeding 95%, effectively reducing energy loss during long-distance high-power transmission. Equipped with comprehensive protection functions against overload, short circuit, over-temperature and low oil pressure, the units feature fast start-up within 10 seconds, stable and reliable operation, low failure rate and long-time continuous working capability. They also support flexible parallel operation and grid-connection to meet different power supply scales.

High-voltage generator set

The High-voltage generator are widely used in industrial, public facility and infrastructure construction fields. In industry, they serve as prime or standby power for large industrial parks, chemical plants, metallurgical factories and mines, ensuring stable high-voltage power for production equipment and avoiding shutdown and economic losses caused by grid interruption. In energy sector, they support wind and photovoltaic power stations for peak shaving and compensation, stabilizing intermittent new energy power supply.

In public facilities, they guarantee uninterrupted operation of core systems in airports, railways, rail transit, large hospitals and data centers, including elevators, fire systems, medical equipment and servers. In construction, they provide temporary prime power for highways, bridges, ports and other large outdoor projects for construction machinery, offices and living areas. They are also ideal for weak-grid overseas areas, remote mining areas and temporary power supply for large events, meeting diversified high-voltage power demands with strong practicability and stability.




  • Your company is factory or trader?

    Our company is factory, we also have our own import-export company named SHANDONG SMART INTERNATIONAL CO.,LTD. however, some China traders use our factory's photos and videos to impersonate us as the actual factory in their foreign promotion.

  • What is difference between Emergency Standby Power and Prime Power for generator?

    Prime Power (PRP): Serves as the primary power source, suitable for areas without a grid (such as remote mining sites, oil fields, and island base stations). It can operate continuously for 24 hours, providing long-term stable power output. Emergency Standby Power (ESP): Functions solely as an emergency backup power source. Continuous operation should not exceed 12 hours, with a 10% overload permitted for up to 1 hour within any 12-hour period. It is used as emergency backup during grid power outages to support critical equipment (such as in hospitals, data centers, and office building elevators). Selection Recommendation: Prioritize selection based on the Prime Power rating to avoid long-term overload operation.

  • Could you supply sample

    Yes, but it is not for free, you need to pay the production cost and logistic cost.

  • Can I visit your company

    Yes, welcome to visit our company and talk about the cooperation. we are biggest factory of generator in our city.

  • Could you accept OEM/ODM

    we provide comprehensive OEM/ODM solutions tailored to the unique needs of global partners in the power equipment sector, covering the full lifecycle from product conceptualization to mass production and after-sales support.

  • How to maintain diesel generator?

    For diesel generator maintenance, the battery charge and the generator engine coolant level are checked. In addition, the generator engine oil level and oil leakage control are performed. It is also necessary to look inside the generator engine tank to check whether there is enough diesel oil.

  • Can a water pump operate under conditions exceeding its rated head?

    In theory, yes, but the efficiency will decrease and it may damage the pump. This will lead to reduced flow rate, increased stress on components, and engine overload. Please select a pump with a suitable rated head.

  • What are the consequences if the diameter of water pump is too small?

    It will restrict flow, increase pressure loss, and reduce output. The pump may overheat, fuel consumption may rise, and issues like erosion and cavitation can occur.

  • How can we ensure a proper power match for water pump?

    The engine power should be sufficient to overcome the resistance of the water pump under the set flow rate and head. Refer to the power requirement curve provided by the manufacturer, while also taking into account the transmission system losses and the engine's load performance.

  • What are the startup steps for water pump?

    Check the fuel and oil levels, prime the pump to expel air, and connect the pipelines. Start the engine, let it idle before increasing speed, while monitoring pressure and flow.

  • How often is routine maintenance required for water pump?

    It should be performed before and after each use. Check the fuel, engine oil, water source, and pipelines, and clean the water pump and engine after operation.

Get the latest price? We will reply as soon as possible (within 12 hours)